Timing adjustment per x number of data bits has been required since DDR3 but DDR4 also has internal reference voltage calibration for DQ bits (VREF_DQ). This voltage sets threshold by which the IO cell determines if a voltage represents a logic high or low. This VREF_DQ value is calibrated per x number of bits in addition to adjusting the timing to try to find the best place to sample the signal.